    I upgraded to ZNET a couple weeks ago and not I am getting these errors almost everyday. I went back to my previous logs from the Z-Troller days and did not find any of these errors.

    Anyone have any ideas?


    11/30/2015
    11/30/2015 12:14 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: 186 Received on interface Z-NET_Wiese
    12/1/2015
    12/1/2015 14:34 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_NETWORK_MANAGEMENT_PRIMARY Received on interface Z-NET_Wiese
    12/1/2015 14:34 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_NETWORK_MANAGEMENT_PRIMARY Received on interface Z-NET_Wiese
    12/2/2015
    12/2/2015 8:10 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_MODE Received on interface Z-NET_Wiese
    12/2/2015 8:10 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_MODE Received on interface Z-NET_Wiese
    12/2/2015 8:10 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_MODE Received on interface Z-NET_Wiese
    12/2/2015 8:10 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_MODE Received on interface Z-NET_Wiese
    12/2/2015 8:10 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_MODE Received on interface Z-NET_Wiese
    12/2/2015 12:21 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: 177 Received on interface Z-NET_Wiese
    12/3/2015
    12/3/2015 13:28 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_HRV_CONTROL Received on interface Z-NET_Wiese
    12/3/2015 19:04 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_MODE Received on interface Z-NET_Wiese
    12/5/2015
    12/5/2015 0:05 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: 131 Received on interface Z-NET_Wiese
    12/5/2015 17:59 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_NETWORK_MANAGEMENT_INCLUSION Received on interface Z-NET_Wiese
    12/6/2015
    12/6/2015 8:36 * Z-Wave Warning Z-NET_Wiese : Secure message received from node 43. It was successfully decrypted but the data sequence ID is out of sequence. (Not Processed)
    12/6/2015 8:36 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: 174 Received on interface Z-NET_Wiese
    12/6/2015 11:33 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: 168 Received on interface Z-NET_Wiese
    12/6/2015 11:33 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: 168 Received on interface Z-NET_Wiese
    12/8/2015
    12/8/2015 23:50 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_PREPAYMENT_ENCAPSULATION Received on interface Z-NET_Wiese
    12/8/2015 23:50 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_PREPAYMENT_ENCAPSULATION Received on interface Z-NET_Wiese
    12/8/2015 23:50 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_PREPAYMENT_ENCAPSULATION Received on interface Z-NET_Wiese
    12/9/2015
    12/9/2015 7:48 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_MODE Received on interface Z-NET_Wiese
    12/9/2015 12:46 * Z-Wave Warning Z-NET_Wiese: Unhandled frame for command class: COMMAND_CLASS_PROPRIETARY Received on interface Z-NET_Wiese

    #2
    I would try a rescan on that node 43.
    HS4Pro on a Raspberry Pi4
    54 Z-Wave Nodes / 21 Zigbee Devices / 108 Events / 767 Devices
    Plugins: Z-Wave / Zigbee Plus / EasyTrigger / AK Weather / OMNI

    HSTouch Clients: 1 Android

    Comment


      #3
      Originally posted by rmasonjr View Post
      I would try a rescan on that node 43.
      Tried a rescan of that device earlier this evening. I am going to watch that one.
      Still puzzled about all the other errors.

      Comment


        #4
        Are you running the latest Z-Wave beta plugin?
        💁‍♂️ Support & Customer Service 🙋‍♂️ Sales Questions 🛒 Shop HomeSeer Products

        Comment


          #5
          Rupp
          Thanks for the response.

          Here is the configuration that I was running when getting the errors
          Current Date/Time: 12/9/2015 20:07:12
          HomeSeer Version: HS3 Pro Edition 3.0.0.217
          Operating System: Microsoft Windows 7 Professional - Work Station
          System Uptime: 12 Days 4 Hours 12 Minutes 25 Seconds
          IP Address: 192.168.3.87
          Number of Devices: 383
          Number of Events: 226
          Enabled Plug-Ins
          2.0.22.0: BL1Wire
          2.0.34.0: BLDSC
          2.0.31.0: BLNetCallerId
          2.0.98.0: BLRadar
          2.0.10.0: BLUSBUIRT
          3.0.0.14: DirecTV
          3.0.0.14: DirecTV
          3.0.0.14: DirecTV
          3.0.0.78: HSTouch Server
          1.0.0.2: Restart
          3.0.0.36: X10
          3.0.1.44: Z-Wave
          I had not as yet upgraded to the latest Z-Wave Beta .52 when these errors occurred. I will upgrade this evening and continue to monitor.

          Comment


            #6
            Rupp
            I have upgraded to the .52 beta release of the Z-Wave plugin.
            I also noticed that the name in the Z-Net was not formatted the same way as the Z-Wave Plugin so I corrected that also.

            Getting the same errors

            12/10/2015
            12/10/2015 2:17 Z-Wave Warning In converting Z-Wave data bytes to a value, Size is reported as 2, but length is 1 and is=B0

            12/10/2015 19:16 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_DEVICE_RESET_LOCALLY Received on interface Z-NETWIESE

            12/10/2015 19:16 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_DEVICE_RESET_LOCALLY Received on interface Z-NETWIESE

            12/10/2015 19:16 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_DEVICE_RESET_LOCALLY Received on interface Z-NETWIESE

            12/11/2015
            12/11/2015 0:28 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_MODE Received on interface Z-NETWIESE

            12/11/2015 3:02 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_ZONE_SENSOR Received on interface Z-NETWIESE

            12/11/2015 3:02 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_ZONE_SENSOR Received on interface Z-NETWIESE

            12/11/2015 3:02 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_SECURITY_PANEL_ZONE_SENSOR Received on interface Z-NETWIESE

            12/11/2015 13:55 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: 159 Received on interface Z-NETWIESE

            12/11/2015 13:55 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: 159 Received on interface Z-NETWIESE

            12/12/2015
            12/12/2015 2:16 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_HRV_CONTROL Received on interface Z-NETWIESE

            12/12/2015 5:00 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_RATE_TBL_MONITOR Received on interface Z-NETWIESE



            Current Date/Time: 12/12/2015 08:41:15
            HomeSeer Version: HS3 Pro Edition 3.0.0.217
            Operating System: Microsoft Windows 7 Professional - Work Station
            System Uptime: 14 Days 16 Hours 46 Minutes 27 Seconds
            IP Address: 192.168.3.87
            Number of Devices: 383
            Number of Events: 226

            Enabled Plug-Ins
            2.0.22.0: BL1Wire
            2.0.34.0: BLDSC
            2.0.31.0: BLNetCallerId
            2.0.98.0: BLRadar
            2.0.10.0: BLUSBUIRT
            3.0.0.14: DirecTV
            3.0.0.14: DirecTV
            3.0.0.14: DirecTV
            3.0.0.80: HSTouch Server
            1.0.0.2: Restart
            3.0.0.36: X10
            3.0.1.52: Z-Wave

            I see this morning that there is a .53 beta now. Going to give that a try for the rest of the weekend and see what happens.

            Comment


              #7
              And the errors continue

              12/12/2015
              12/12/2015 12:46 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: 191 Received on interface Z-NETWIESE

              12/13/2015
              12/13/2015 01:57 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: 161 Received on interface Z-NETWIESE

              12/13/2015 01:57 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: 161 Received on interface Z-NETWIESE

              12/13/2015 05:43 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: COMMAND_CLASS_HRV_CONTROL Received on interface Z-NETWIESE

              12/13/2015 06:17 Z-Wave Warning Z-NETWIESE: Unhandled frame for command class: 172 Received on interface Z-NETWIESE



              Current Date/Time: 12/14/2015 14:01:12
              HomeSeer Version: HS3 Pro Edition 3.0.0.217
              Operating System: Microsoft Windows 7 Professional - Work Station
              System Uptime: 1 Day 5 Hours 4 Minutes 29 Seconds
              IP Address: 192.168.3.87
              Number of Devices: 383
              Number of Events: 227

              Enabled Plug-Ins
              2.0.22.0: BL1Wire
              2.0.34.0: BLDSC
              2.0.31.0: BLNetCallerId
              2.0.98.0: BLRadar
              2.0.10.0: BLUSBUIRT
              3.0.0.14: DirecTV
              3.0.0.14: DirecTV
              3.0.0.14: DirecTV
              3.0.0.80: HSTouch Server
              1.0.0.2: Restart
              3.0.0.36: X10
              3.0.1.53: Z-Wave

              Should I open a trouble ticket with the help desk before my 30 days after purchase are up?

              Searching the internet I found that there is a Bugzilla ticket opened for some similar issues. One update is for European Z-Net and I can not tell what interface the other is using. I will add to the Bugzilla ticket
              Bug 2229 - Z-Wave Unhandled Frame errors
              Last edited by rwiese1; December 14, 2015, 03:50 PM. Reason: Addiing informaion about a similar Bugzilla ticket

              Comment


                #8
                (Bump)

                Is there any way to figure out which node is causing these errors? I have two houses. One with a Z-Stick with absolutely NO errors. The other with a Z-NET, with which I get TONS of these kinds of errors daily.

                Any movement on the Bugzilla?

                Comment


                  #9
                  I asked about these warnings and they indicate a command class that is being received by the Z-Wave interface that HS3 doesn't support. Rich said he would remove these warnings as they currently do not show the node id and therefore have no value.
                  💁‍♂️ Support & Customer Service 🙋‍♂️ Sales Questions 🛒 Shop HomeSeer Products

                  Comment


                    #10
                    Originally posted by mikedr View Post
                    (Bump)

                    Is there any way to figure out which node is causing these errors? I have two houses. One with a Z-Stick with absolutely NO errors. The other with a Z-NET, with which I get TONS of these kinds of errors daily.

                    Any movement on the Bugzilla?
                    I have had similar issues - when I get loads of these errors in the logs the ZNet will either crash after a period of time, turn every zwave device on or randomly turn individual zwave devices on.

                    Once I resolved the issue for a few days by restoring an older ZNet backup. However I did work out the node in the end - turn on zwave debug logging and open the log file that is generated - it does show the node.

                    Comment


                      #11
                      Originally posted by Rupp View Post
                      I asked about these warnings and they indicate a command class that is being received by the Z-Wave interface that HS3 doesn't support. Rich said he would remove these warnings as they currently do not show the node id and therefore have no value.
                      Thanks! Do you know if this will occur soon? I assume it'll be a Z-Wave plugin update?